8 sonuçlar

    • eCLIQ User Key

      Function
      Used in combination with the eCLIQ cylinder, the eCLIQ User Key can be programmed directly with authorizations and time profiles.
      The key also collects usage information to create complete access audit trails.

      Applications
      The eCLIQ® User Key Available in three versions (Basic, Time and Dynamic).
      This key can be used with eCLIQ Remote Programming Devices.

      Features
      Schedule: 32 week-based time intervals
      Audit trail: 1000 events
      Color-coded LED indicators: Green - Authorized; Red - Unauthorized; Red-green-red - Out of schedule; Blinking red - Low battery
      Supports remote programming of authorizations and scheduling

      Specifications
      Protected against temporary immersion in water (IP67)
      Temperature range: 0°C - 70°C
      Encrypted (AES) communication between the key and the cylinder or software
      Powered by a CR2032 3V lithium battery; Battery replacement in the key does not require tools.
      Battery lifetime: 3 years or 30,000 operations
      Standard design: black; other colors are available for the key cover
      Special keys:
      - Beluga: Designed for use in outdoor installation (-30°C to +50°C), for example, storage in the fire service safe. The Beluga key's battery is not exchangeable.
      - ATEX certified: user keys that are certified for use in potentially-explosive areas in Zone 1 (II 2G Ex ib IIB T4)
      - RFID: Key with integrated RFID chip for integration into control of transponder-based systems, e.g. access control systems.

    • eCLIQ Local Programing Device (LPD)

      Function
      The eCLIQ® Local Programming Device (LPD) is used to connect eCLIQ® keys and cylinders to the software (CLIQ® Manager and/or CLIQ® Web Manager), via secure communication.

      Features
      Provides secure access to the eCLIQ® system software
      Reads and uploads audit trails from eCLIQ® keys
      Updates eCLIQ® Keys with the latest authorizations and time schedules
      Uploads tasks from CLIQ® software to the C-Key(s)

      Specifications
      Computer connectivity via micro USB cable
      Power supply: powered through the micro USB cable

    • CLIQ Web Manager Software

      Function
      A web-based software program, CLIQ® Web Manager is used to manage the eCLIQ® Remote system.
      User-friendly and intuitive, system administrators use it to remotely manage the day-to-day functionality of the eCLIQ® Remote system.

      Applications
      As a web-based solution, the CLIQ® Web Manager provides access to the system's database from any computer with an Internet connection and has been specifically designed to handle large, decentralized systems.

      Features
      Secure login via a control key and PIN code for multiple administrators
      Advanced search and filter options
      Manages and creates: Access permissions; Audit trails - including activities from remote devices; Time-based authorization; Recurring validation; Reports
      Supports remote programming device management
      Enables system grouping into manageable domains
      Allows remote key programming
      Key and personnel management

      Specifications
      Web browser: Internet Explorer 7 and up
      Highly secured network connections, 128-bit SSL encryption as well as the security afforded by software certificates on client and server
      Available in multi-language versions
      License options are available per system size

    • eCLIQ Remote Wall Programming Device (WPD)

      Function
      Embedded with its own IP address, the online eCLIQ® Remote Wall Programming Device allows users to remotely program eCLIQ User keys and C-Keys.

      Features
      Makes authorization changes in Dynamic keys
      Actions time-profile changes in Dynamic and Time keys
      Retrieves audit trails from Dynamic and Time keys
      Revalidates keys
      Automatically syncs keys' time settings
      Provides visual and audio indicators of operational status and activity progress
      Updates eCLIQ® key's firmware

      Specifications
      IP42
      Power supply: 12-24 V AC/DC or Power over Ethernet (PoE) - class 1 IEEE 802.3 af. (Supply must be LPS approved)
      'Anti vandal' model: IP65, Vandalism-resistant IK9

    • CLIQ Manager Software

      Function
      Locally installed CLIQ® Manager software is used for the day-to-day management of the eCLIQ® system. With it, system administers can perform a variety of tasks based on the specific needs of their environment.

      Features
      Secure login via a control key and PIN code
      Manages and creates: Access permissions; Audit trails; Time-based authorization; Reports
      Key and personnel management

      Specifications
      Installation options: Local installation; Centralized database
      OS - MS Windows 2000/XP/ VISTA/Windows 7/8/10
      Hardware requirements: MS Windows compatible PC, Pentium IV-1,5 GHz, 50MB free hard disk memory, 512 MB RAM

      Licensing options
      CLIQ® Manager 50 - One eCLIQ® system with up to 50 eCLIQ® elements in the system
      CLIQ® Manager 200 - One eCLIQ® system with up to 200 eCLIQ® elements in the system
      CLIQ® Single Manager - One eCLIQ® system with unlimited quantity of eCLIQ® elements
      CLIQ® Multi System Manager - Multiple eCLIQ® systems with an unlimited quantity of eCLIQ® elements

    • eCLIQ Cylinder

      Function
      The eCLIQ cylinder is used in combination with the eCLIQ key enabling the collection and storage of information about when the cylinder has been accessed and with which key.
      In addition, the cylinder stores a list of authorized and unauthorized eCLIQ keys to ensure only enabled keys have access.

      Applications
      The eCLIQ® cylinder is available in a wide range of cylinder applications including Euro (double or single), rim, mortise, kik, padlocks, and more.

      Features
      Audit trail standard memory: 100 events
      Audit trail extended memory: 1000 events

      Specifications
      IP54 (dust and rain protection cap available for one or both sides - IP55)
      Temperature range: -25°C - 85°C
      Encrypted (AES) communication between cylinder and key/c-key
      Available in a variety of finishes
      Minimum length: 28 mm (Euro model)
      Modular (from 30mm, by 5 or 10mm extentions)
      Maintenance-free up to 200,000 cycles (includes integrated lubricant reserve)
      Power supplied via the eCLIQ® key's embedded battery

    • eCLIQ Remote Mobile Programming Device (MPD)

      Function
      Using a cellular phone or computer as a modem, the eCLIQ® Remote Mobile Programming Device (MPD) allows user to program eCLIQ® keys and C-Keys on-the-go.

      Features
      Makes authorization changes in Dynamic keys
      Actions time-profile changes inTime keys
      Retrieves audit trails from Dynamic and Time keys
      Revalidates keys
      Automatically syncs keys' time settings
      Provides visual and audio indicators of operational status and activity progress

      Specifications
      IP42
      Powered by 4 x AAA batteries

      Connection options
      Via cellular telephone through Bluetooth. Connects to conventional cellular telephone models without the need for software installation
      Via computer through USB connection between Mobile PD and computer using a simple application as a bridge for network connections. Can be powered through the USB cable.

    • eCLIQ Control Key (C-Key)

      Function
      The eCLIQ® Control Key (C-Key) manages the electronic communication provided by the eCLIQ® system.
      It provides users secure access to the system software and the ability to transfer information between the software and cylinders.

      Applications
      Each eCLIQ® system must have at least one C-Key, referred to as the Master C-Key (MCK). The MCK is used to transfer information from eCLIQ® cylinders to the software and not to open them.
      For systems with more than one administrator, it is possible to utilize additional C-Keys, also referred to as a Normal C-Key (NCK).

      Features
      Update key authorization lists within cylinders
      Transfers audit trail information from cylinder to software
      Facilitates secured access to the software

      Specifications
      Protected against temporary immersion in water (IP67)
      Temperature range: 0°C - 70°C
      Encrypted (AES) communication between the key and the cylinder or software
      Powered by a CR2032 3V lithium battery; Battery replacement in the key does not require tools.
      Battery lifetime: 3 years or 30,000 operations
      Standard desigh: black; other colors are available for the key cover
      Special keys:
      - Beluga: Designed for use in outdoor installation (-30°C to +50°C), for example, storage in the fire service safe. The Beluga key's battery is not exchangeable.
      - ATEX certified: user keys that are certified for use in potentially-explosive areas in Zone 1 (II 2G Ex ib IIB T4)
      - RFID: Key with integrated RFID chip for integration into control of transponder-based systems, e.g. access control systems.

    8/8 gösteriliyor