8 sonuçlar
Function
Used in combination with the eCLIQ cylinder, the eCLIQ User Key can be programmed directly with authorizations and time profiles.
The key also collects usage information to create complete access audit trails.
Applications
The eCLIQ® User Key Available in three versions (Basic, Time and Dynamic).
This key can be used with eCLIQ Remote Programming Devices.
Features
Schedule: 32 week-based time intervals
Audit trail: 1000 events
Color-coded LED indicators: Green - Authorized; Red - Unauthorized; Red-green-red - Out of schedule; Blinking red - Low battery
Supports remote programming of authorizations and scheduling
Specifications
Protected against temporary immersion in water (IP67)
Temperature range: 0°C - 70°C
Encrypted (AES) communication between the key and the cylinder or software
Powered by a CR2032 3V lithium battery; Battery replacement in the key does not require tools.
Battery lifetime: 3 years or 30,000 operations
Standard design: black; other colors are available for the key cover
Special keys:
- Beluga: Designed for use in outdoor installation (-30°C to +50°C), for example, storage in the fire service safe. The Beluga key's battery is not exchangeable.
- ATEX certified: user keys that are certified for use in potentially-explosive areas in Zone 1 (II 2G Ex ib IIB T4)
- RFID: Key with integrated RFID chip for integration into control of transponder-based systems, e.g. access control systems.
Function
The eCLIQ® Local Programming Device (LPD) is used to connect eCLIQ® keys and cylinders to the software (CLIQ® Manager and/or CLIQ® Web Manager), via secure communication.
Features
Provides secure access to the eCLIQ® system software
Reads and uploads audit trails from eCLIQ® keys
Updates eCLIQ® Keys with the latest authorizations and time schedules
Uploads tasks from CLIQ® software to the C-Key(s)
Specifications
Computer connectivity via micro USB cable
Power supply: powered through the micro USB cable
Function
A web-based software program, CLIQ® Web Manager is used to manage the eCLIQ® Remote system.
User-friendly and intuitive, system administrators use it to remotely manage the day-to-day functionality of the eCLIQ® Remote system.
Applications
As a web-based solution, the CLIQ® Web Manager provides access to the system's database from any computer with an Internet connection and has been specifically designed to handle large, decentralized systems.
Features
Secure login via a control key and PIN code for multiple administrators
Advanced search and filter options
Manages and creates: Access permissions; Audit trails - including activities from remote devices; Time-based authorization; Recurring validation; Reports
Supports remote programming device management
Enables system grouping into manageable domains
Allows remote key programming
Key and personnel management
Specifications
Web browser: Internet Explorer 7 and up
Highly secured network connections, 128-bit SSL encryption as well as the security afforded by software certificates on client and server
Available in multi-language versions
License options are available per system size
Function
Embedded with its own IP address, the online eCLIQ® Remote Wall Programming Device allows users to remotely program eCLIQ User keys and C-Keys.
Features
Makes authorization changes in Dynamic keys
Actions time-profile changes in Dynamic and Time keys
Retrieves audit trails from Dynamic and Time keys
Revalidates keys
Automatically syncs keys' time settings
Provides visual and audio indicators of operational status and activity progress
Updates eCLIQ® key's firmware
Specifications
IP42
Power supply: 12-24 V AC/DC or Power over Ethernet (PoE) - class 1 IEEE 802.3 af. (Supply must be LPS approved)
'Anti vandal' model: IP65, Vandalism-resistant IK9
Function
Locally installed CLIQ® Manager software is used for the day-to-day management of the eCLIQ® system. With it, system administers can perform a variety of tasks based on the specific needs of their environment.
Features
Secure login via a control key and PIN code
Manages and creates: Access permissions; Audit trails; Time-based authorization; Reports
Key and personnel management
Specifications
Installation options: Local installation; Centralized database
OS - MS Windows 2000/XP/ VISTA/Windows 7/8/10
Hardware requirements: MS Windows compatible PC, Pentium IV-1,5 GHz, 50MB free hard disk memory, 512 MB RAM
Licensing options
CLIQ® Manager 50 - One eCLIQ® system with up to 50 eCLIQ® elements in the system
CLIQ® Manager 200 - One eCLIQ® system with up to 200 eCLIQ® elements in the system
CLIQ® Single Manager - One eCLIQ® system with unlimited quantity of eCLIQ® elements
CLIQ® Multi System Manager - Multiple eCLIQ® systems with an unlimited quantity of eCLIQ® elements
Function
The eCLIQ cylinder is used in combination with the eCLIQ key enabling the collection and storage of information about when the cylinder has been accessed and with which key.
In addition, the cylinder stores a list of authorized and unauthorized eCLIQ keys to ensure only enabled keys have access.
Applications
The eCLIQ® cylinder is available in a wide range of cylinder applications including Euro (double or single), rim, mortise, kik, padlocks, and more.
Features
Audit trail standard memory: 100 events
Audit trail extended memory: 1000 events
Specifications
IP54 (dust and rain protection cap available for one or both sides - IP55)
Temperature range: -25°C - 85°C
Encrypted (AES) communication between cylinder and key/c-key
Available in a variety of finishes
Minimum length: 28 mm (Euro model)
Modular (from 30mm, by 5 or 10mm extentions)
Maintenance-free up to 200,000 cycles (includes integrated lubricant reserve)
Power supplied via the eCLIQ® key's embedded battery
Function
Using a cellular phone or computer as a modem, the eCLIQ® Remote Mobile Programming Device (MPD) allows user to program eCLIQ® keys and C-Keys on-the-go.
Features
Makes authorization changes in Dynamic keys
Actions time-profile changes inTime keys
Retrieves audit trails from Dynamic and Time keys
Revalidates keys
Automatically syncs keys' time settings
Provides visual and audio indicators of operational status and activity progress
Specifications
IP42
Powered by 4 x AAA batteries
Connection options
Via cellular telephone through Bluetooth. Connects to conventional cellular telephone models without the need for software installation
Via computer through USB connection between Mobile PD and computer using a simple application as a bridge for network connections. Can be powered through the USB cable.
Function
The eCLIQ® Control Key (C-Key) manages the electronic communication provided by the eCLIQ® system.
It provides users secure access to the system software and the ability to transfer information between the software and cylinders.
Applications
Each eCLIQ® system must have at least one C-Key, referred to as the Master C-Key (MCK). The MCK is used to transfer information from eCLIQ® cylinders to the software and not to open them.
For systems with more than one administrator, it is possible to utilize additional C-Keys, also referred to as a Normal C-Key (NCK).
Features
Update key authorization lists within cylinders
Transfers audit trail information from cylinder to software
Facilitates secured access to the software
Specifications
Protected against temporary immersion in water (IP67)
Temperature range: 0°C - 70°C
Encrypted (AES) communication between the key and the cylinder or software
Powered by a CR2032 3V lithium battery; Battery replacement in the key does not require tools.
Battery lifetime: 3 years or 30,000 operations
Standard desigh: black; other colors are available for the key cover
Special keys:
- Beluga: Designed for use in outdoor installation (-30°C to +50°C), for example, storage in the fire service safe. The Beluga key's battery is not exchangeable.
- ATEX certified: user keys that are certified for use in potentially-explosive areas in Zone 1 (II 2G Ex ib IIB T4)
- RFID: Key with integrated RFID chip for integration into control of transponder-based systems, e.g. access control systems.