Products
Filter
26 resultaten
CLIQ Manager Software
Function
Locally installed CLIQ® Manager software is used for the day-to-day management of the eCLIQ® system. With it, system administers can perform a variety of tasks based on the specific needs of their environment.Features
Secure login via a control key and PIN code
Manages and creates: Access permissions; Audit trails; Time-based authorization; Reports
Key and personnel managementSpecifications
Installation options: Local installation; Centralized database
OS - MS Windows 2000/XP/ VISTA/Windows 7/8/10
Hardware requirements: MS Windows compatible PC, Pentium IV-1,5 GHz, 50MB free hard disk memory, 512 MB RAMLicensing options
CLIQ® Manager 50 - One eCLIQ® system with up to 50 eCLIQ® elements in the system
CLIQ® Manager 200 - One eCLIQ® system with up to 200 eCLIQ® elements in the system
CLIQ® Single Manager - One eCLIQ® system with unlimited quantity of eCLIQ® elements
CLIQ® Multi System Manager - Multiple eCLIQ® systems with an unlimited quantity of eCLIQ® elementsCLIQ Web Manager Software
Function
A web-based software program, CLIQ® Web Manager is used to manage the eCLIQ® Remote system.
User-friendly and intuitive, system administrators use it to remotely manage the day-to-day functionality of the eCLIQ® Remote system.Applications
As a web-based solution, the CLIQ® Web Manager provides access to the system's database from any computer with an Internet connection and has been specifically designed to handle large, decentralized systems.Features
Secure login via a control key and PIN code for multiple administrators
Advanced search and filter options
Manages and creates: Access permissions; Audit trails - including activities from remote devices; Time-based authorization; Recurring validation; Reports
Supports remote programming device management
Enables system grouping into manageable domains
Allows remote key programming
Key and personnel managementSpecifications
Web browser: Internet Explorer 7 and up
Highly secured network connections, 128-bit SSL encryption as well as the security afforded by software certificates on client and server
Available in multi-language versions
License options are available per system sizeCode-Handle® (DIN standard)
Function
Access control via an automatic locking mechanism built within the handle that helps prevent unauthorized access and is operated with personal code.
Applications
For interior use.
Compatible with most types of locking/latching products.
Features
Keyless locking
2 operating modes: Automatic locking; Manual locking
4-to 6-digit personal code for opening
Locks only from the door's exterior side
Simple operation
Easy installation (including retrofit)
Wire-free installation
Low-cost maintenance
Specifications
Door width: 35-80mm
7 or 8mm spindle
Up to 9 distinct codes
Indication light
Indication sound
Battery: 2 x CR2 3V lithium
Material: Brushed stainless steel and satin chrome zinc
Tested with a minimum of 100,000 operations, according to EN 1906
Fire tested according to EN 1363Code-Handle® 8815 - Electronic Security Handles
Application
For easy and convenient locking/unlocking of interior door. E.g. Office doors, consultation rooms, store applications (e.g. staff doors)
Patented product, It's a handle with built-in code lock. The handle is battery operated and no wiring is required during installation.Function
• For indoor use only.
• Fits lock houses with Japanese standards.
• 4-6 digit code.
• Two CR2, 3V lithium batteries. (Tested for a durability of about 30,000 cycles of 1 opening and 1 locking operation).
• Indication for battery replacement.
• Tested for a durability of at least 100,000 operations, according to EN 1906.
• Fire tested according to EN 1363.Features
• Easy locking / unlocking without keys.
• No wiring is needed.
• Main code and up to 9 different user codes.
• Blocking function if wrong code is entered five times.
• Selecting automatic or manual locking.
• "Simplicity creates security."Code-Handle® 8816 (ANSI style)
Function
Access control via an automatic locking mechanism built within the handle that helps prevent unauthorized aces and is operated with personal code.
Applications
For interior use.
Features
Keyless locking
2 operating modes: Automatic locking; Manual locking
4-to 6-digit personal code for opening
Locks only from the door's exterior side
Simple operation
Easy installation (including retrofit)
Wire-free
Low-cost maintenance installation
Specifications
Max. door width 2 ¼" (57mm)
8mm spindle
Tubular latch adjustable backset 2 3/8" (60mm) to 2 ¾" (70mm)
Up to 9 distinct codes
Indication light
Indication sound
Battery: 2 x CR2 3V lithiumCode-Handle® Long Plate (DIN standard)
Function
Access control via an automatic locking mechanism built within the handle that helps prevent unauthorized access and is operated with personal code.
Applications
For indoor use.
Compatible with most types of locking/latching products.
Features
Keyless locking
2 operating modes: Automatic locking; Manual locking
4-to 6-digit personal code for opening
Locks only from the door's exterior side
Simple operation
Easy installation (including retrofit)
Wire-free installation
Low-cost maintenance
Specifications
Door width: 35-80mm
7 or 8mm spindle
Up to 9 distinct codes
Indication light
Indication sound
Battery: 2 x CR2 3V lithium
Material: Brushed stainless steel and satin chrome zinc
Tested with a minimum of 100,000 operations, according to EN 1906
Fire tested according to EN 1363
Options
Distance between handle and cylinder (CC): 55mm; 70mm; 72mm; 85mm; No cylinder holeeCLIQ Control Key (C-Key)
Function
The eCLIQ® Control Key (C-Key) manages the electronic communication provided by the eCLIQ® system.
It provides users secure access to the system software and the ability to transfer information between the software and cylinders.Applications
Each eCLIQ® system must have at least one C-Key, referred to as the Master C-Key (MCK). The MCK is used to transfer information from eCLIQ® cylinders to the software and not to open them.
For systems with more than one administrator, it is possible to utilize additional C-Keys, also referred to as a Normal C-Key (NCK).Features
Update key authorization lists within cylinders
Transfers audit trail information from cylinder to software
Facilitates secured access to the softwareSpecifications
Protected against temporary immersion in water (IP67)
Temperature range: 0°C - 70°C
Encrypted (AES) communication between the key and the cylinder or software
Powered by a CR2032 3V lithium battery; Battery replacement in the key does not require tools.
Battery lifetime: 3 years or 30,000 operations
Standard desigh: black; other colors are available for the key cover
Special keys:
- Beluga: Designed for use in outdoor installation (-30°C to +50°C), for example, storage in the fire service safe. The Beluga key's battery is not exchangeable.
- ATEX certified: user keys that are certified for use in potentially-explosive areas in Zone 1 (II 2G Ex ib IIB T4)
- RFID: Key with integrated RFID chip for integration into control of transponder-based systems, e.g. access control systems.eCLIQ Cylinder
Function
The eCLIQ cylinder is used in combination with the eCLIQ key enabling the collection and storage of information about when the cylinder has been accessed and with which key.
In addition, the cylinder stores a list of authorized and unauthorized eCLIQ keys to ensure only enabled keys have access.Applications
The eCLIQ® cylinder is available in a wide range of cylinder applications including Euro (double or single), rim, mortise, kik, padlocks, and more.Features
Audit trail standard memory: 100 events
Audit trail extended memory: 1000 eventsSpecifications
IP54 (dust and rain protection cap available for one or both sides - IP55)
Temperature range: -25°C - 85°C
Encrypted (AES) communication between cylinder and key/c-key
Available in a variety of finishes
Minimum length: 28 mm (Euro model)
Modular (from 30mm, by 5 or 10mm extentions)
Maintenance-free up to 200,000 cycles (includes integrated lubricant reserve)
Power supplied via the eCLIQ® key's embedded batteryeCLIQ Local Programing Device (LPD)
Function
The eCLIQ® Local Programming Device (LPD) is used to connect eCLIQ® keys and cylinders to the software (CLIQ® Manager and/or CLIQ® Web Manager), via secure communication.Features
Provides secure access to the eCLIQ® system software
Reads and uploads audit trails from eCLIQ® keys
Updates eCLIQ® Keys with the latest authorizations and time schedules
Uploads tasks from CLIQ® software to the C-Key(s)Specifications
Computer connectivity via micro USB cable
Power supply: powered through the micro USB cableeCLIQ Remote Mobile Programming Device (MPD)
Function
Using a cellular phone or computer as a modem, the eCLIQ® Remote Mobile Programming Device (MPD) allows user to program eCLIQ® keys and C-Keys on-the-go.Features
Makes authorization changes in Dynamic keys
Actions time-profile changes inTime keys
Retrieves audit trails from Dynamic and Time keys
Revalidates keys
Automatically syncs keys' time settings
Provides visual and audio indicators of operational status and activity progressSpecifications
IP42
Powered by 4 x AAA batteriesConnection options
Via cellular telephone through Bluetooth. Connects to conventional cellular telephone models without the need for software installation
Via computer through USB connection between Mobile PD and computer using a simple application as a bridge for network connections. Can be powered through the USB cable.eCLIQ Remote Wall Programming Device (WPD)
Function
Embedded with its own IP address, the online eCLIQ® Remote Wall Programming Device allows users to remotely program eCLIQ User keys and C-Keys.Features
Makes authorization changes in Dynamic keys
Actions time-profile changes in Dynamic and Time keys
Retrieves audit trails from Dynamic and Time keys
Revalidates keys
Automatically syncs keys' time settings
Provides visual and audio indicators of operational status and activity progress
Updates eCLIQ® key's firmwareSpecifications
IP42
Power supply: 12-24 V AC/DC or Power over Ethernet (PoE) - class 1 IEEE 802.3 af. (Supply must be LPS approved)
'Anti vandal' model: IP65, Vandalism-resistant IK9eCLIQ User Key
Function
Used in combination with the eCLIQ cylinder, the eCLIQ User Key can be programmed directly with authorizations and time profiles.
The key also collects usage information to create complete access audit trails.Applications
The eCLIQ® User Key Available in three versions (Basic, Time and Dynamic).
This key can be used with eCLIQ Remote Programming Devices.Features
Schedule: 32 week-based time intervals
Audit trail: 1000 events
Color-coded LED indicators: Green - Authorized; Red - Unauthorized; Red-green-red - Out of schedule; Blinking red - Low battery
Supports remote programming of authorizations and schedulingSpecifications
Protected against temporary immersion in water (IP67)
Temperature range: 0°C - 70°C
Encrypted (AES) communication between the key and the cylinder or software
Powered by a CR2032 3V lithium battery; Battery replacement in the key does not require tools.
Battery lifetime: 3 years or 30,000 operations
Standard design: black; other colors are available for the key cover
Special keys:
- Beluga: Designed for use in outdoor installation (-30°C to +50°C), for example, storage in the fire service safe. The Beluga key's battery is not exchangeable.
- ATEX certified: user keys that are certified for use in potentially-explosive areas in Zone 1 (II 2G Ex ib IIB T4)
- RFID: Key with integrated RFID chip for integration into control of transponder-based systems, e.g. access control systems.SMARair Wall Reader Universal Design
Function
The SMARTair Wall Reader is a unique and elegant access control solution designed for simple installation and operation.
The Wall Reader operates magnet locks, electric strike or electronic locks. All the control elements are on the inside of the door to enhance security.
Applications
Access control for commercial and institutional facilities, including offices, hospitals, factories, assisted living facilities, schools, sports clubs and more.
Management options*
Standalone; Offline; Update-On-Card (UOC); Wireless
* Products are upgradable from Standalone to Wireless
Features
Simple installation
Simple operation
4-digit code
System management through easy-to-use software including: Authorizations; Time schedules; Daylight savings time and holidays; Deletion and replacement of lost tags; Audit trail; Temporary blockage; 4 operation modes - Standard, Open, First person in, Dual user (available only in the wireless version)
Scales up to 64,000 user cards and up to 64,000 doors per system
Specifications
13.56 MHz, MIFARE® DESFire or iClass technology
Contactless cards/tags
2-4 cm read/write distance
Temperature range: -10°C to 80°C
12V AC/DC power
Consumption: Relay not active - 20µA; Relay active - 150mA
Relay: NO, NC, C
Wireless frequency: 868MHz or 915 MHz
Options
With or without keypad (with keypad is not available as Standalone): RFID only; RFID and code; Code onlySMARTair® ANSI
Function
Manages access to multiple doors with easy-to-use portable programmer and encoded, contactless electronic cards.
Applications
Access control for commercial and institutional facilities, including offices, hospitals, factories, assisted living facilities, schools, sports clubs and more.
Management options*
Standalone; Offline; Update-On-Card (UOC); Wireless
* Products are upgradable from Standalone to Wireless
Features
Wire-free installation
Simple operation
System management through easy-to-use software including: Authorizations; Time schedules; Daylight savings time and holidays; Deletion and replacement of lost tags; Audit trail (including registration of the internal handle); Escape - return feature; Door status indication: Door open, Door closed; 4 operation modes - Standard, Open, First person in, Dual user (available only in the wireless version)
Scales up to 64,000 user cards and up to 64,000 doors per system
Specifications
13.56 MHz, HID iClass® DESFire & MIFARE® RFID technology
Contactless RFID cards / tags / fobs / silicon & disposable wristbands
2 possible memory configurations: 1,500 users and 600 events in the event log; 1,000 users and 1,000 events in the event log
2 to 4 cm read/write distance
Powered by 3 x AA batteries
Conforms to ANSI grade 1
ANSI A115 prep modified for through-bolts
ADA-compliant levers
RF module frequency: 915 MHz
Shabbat compliant
UL-3hour fire rate latch bolt
Door width: 1 3/8" (35mm); 1 ¾" (44.5mm); 2 ¼" (57mm)
Options
Handles: SENA, TOLEDO
Finish: Inox, Satin chrome, PVD polished brass, PVD satin brass
Privacy feature
May be installed with or without cylinder
Cylinder options: Classic, Interactive®+, MT5®, 7x7, Integrator® platforms; Keyed different, Keyed alike; Master keying; '3 in 1' (changeable combination); FleX Control
Internal / external models available
Cylindrical version: 2¾" (70mm) backset - standard; 2⅜" (60mm) backset - available
Mortise version: Automatic deadbolt - standard; Latch only version - available
Installation with a Panic Exit Device (PED)SMARTair® Cabinet Lock (E-Motion)
Function
E-Motion is an electronic lock for lockers which may be integrated into the SMARTair system.
Features
Simple operation
System management through easy-to-use software
2 operation modes
High traffic:
All lockers are available to all users. Any user can select a free locker and lock it by presenting his/her card.
While the locker is locked, other users cannot open it, and the user cannot lock another locker.
Once the user has opened the locker, it is available to other users again.
User assigned:
Through the E-Motion or SMARTair software, a specific locker can be assigned to one or more users.
This mode of operation supports various access control features: authorizations, time schedules, daylight savings time and holidays, cancellation and replacement of lost tags, audit trail, temporary blockage, etc.
Electronic features
Reader module:
13.56 MHz, MIFARE® RFID technology
ISO 14443A
Contact-less cards/tags (MIFARE Classic 1K, 4K and ULTRALIGHT)
Reading range: 10mm with standard credentials
LED indications (access authorized, access denied, low battery, etc.)
Control Unit:
Non-volatile memory
Up to 1500 users
Up to 1000 events recorded in audit trail
Real-time clock and calendar
Battery module:
Type: 3 x LR03 AAA 1.5V alkaline batteries
Estimated duration: 20,000 operations or 3 years
Changing the batteries is easy and simple; no need to disassemble the lock
Specifications
Temperature range (external side): from -20°C to 70°C
85% humidity without condensation
Fire certificate: 30', 60' and 90' UNFEN 1634:2000
IP55
Dimensions
Door width (3 models): 2-12mm; 12-15mm; 15-25mm
'Long' or 'Short' footprintSMARTair® Encoder
Function
The SMARTair Encoder is a device that encodes and reads user credentials using the SMARTair software.
Credentials
Read/write contactless chip identification technology RFID 13.56 MHz: MIFARE Classic 1K, 4K, and ULTRALIGHT, DESFire
; iClass 2k/2, 16k/2, 16k/16, 32k
Credential type: Card; Tag; Silicon bracelet; Transponder sticker; SynerKey
Specifications
Power cable − supplied with the encoder: Input - 100-240V 50/60 Hz 1.0A; Output - 7.5V 1.2A
USB connection to the PC − supplied with the encoder
Red & green indicationsSMARTair® Escutcheon (Offline, UOC, Wireless)
The SMARTair wireless and battery powered escutcheons are ideal for transit, office or meeting room doors. The wide range of escutcheons offer a RFID reader amd locking mechanism in one for all kind of doors.
Technical Data
Door profiles - Suitable for wooden, narrow or glass doors
Traffic volume - meduim to high
Exterior usage - IP54 (Xetreme version) Up to 85% humidity -20 °C to +70 °C
Hardware compatibility and installation - High retrofit (compatible with most common mortise locks). Drilling, no cabling. Doors from 30mm up to 110mm (thicker doors may be possible on demand)
Power supply - Battery (from 60.000 to 80.000 cycles)* max. 2 years standby**
Types of batteries:: 3 LR03 AAA 1.5V alkaline batteries
Multi-authentication - RFID and PIN
Status informatin - Handle usage. Thumb turn usage: only in privacy model/ door position: door sensor ot included. No (normally open) connection. Override cylinder (in combination with special mortise lock)
Certification - CE (EMC, R&TTE). ROHS, REACH, WEE. EN1634 (Fire)
RFID tegnologies - HID iClass(R). MIFARE Classic and Ultralight SKIDATA. DESFire.
System management upgradability - Escutcheons can be upgraded from standalone > Offline. Update on Card > Wireless online by:
- Adding RF Module
- Fireware upgrade
- Change of internal cover (plastic top)
* Depending on reading technology (MIFARE), iClass etc.)
** Depending on cycles per day.
Electronic Technical Caracteristics
Reader Module- Activation Mode: The escutcheon is activated without any previous contact with the escutcheon, just approching the credential, ensuring an efficient power consumption.
- Reading distance: 2-4 cm read/write distance with standard RFID credentials.
- Emergency openingL Jack connection is available to connect the portable programmer and emergency kit.
- RFID reader with capacitive keypad and backlighting LEDs (green/red/blue) for different warning signals: access authorized or denied, low battery level, etc.
- Buzzer included for PIN confirmation and access denied.
- Operating modes:
-- Only RFID.
-- Only PIN.
-- RFID + PIN.
-- PIN + RFID.
Control Unit- Upgradeable firmware.
- None-volatile memory. The escutcheon can be programmed to operate in 2 modes:
-- Normal mode: 1500 users and 600 events.
-- High traffic door: unlimited number of users filtered into 48 groups (permissions). Stores 1000 events.- Number of PINs:
-- PIN + RFID (or RFID + PIN): unlimited PINs (stored in card).
-- Only PIN mode: 8.
-- 1 door PIN.
-- 7 common PINs per installation selectable in each door.
-- Type of PIN: 4-6 digits.- Real-time clock and calendar:
-- 14 time zones with 5 time periods (week days and holidays selectable).
-- State tables: configure 20 changes of operating modes in a door per day (switch door from lock to unlock).
-- Yearly calendar: is updated every month automatically by the wireless system.
-- Automatic DST: Daylight Saving Time change. Udatedwith calendar.- Operating modes:
-- Standard: Default operating mode. Freewheeling handle until valid credential presented, then allows to open the door for 4-10 seconds (configurable).
-- Standard ADA: Standard with double opening time.
-- Passage mode: Escutcheon is always in open mode (cofigured by zones or by authorized user after doubke badging).
-- Dpuble user: Two valid credentials needed to open the door.
-- First User: lock in standard mode until first valid user enters, then will remain in passage mode (until closed by authorized user or automatically by time zone, state tables).Battery Module
- Easy battery change.
- Maintains clock/calendar for 5 minutes without batteries.
- Battery status reported on every event or once a day if no event happens.
RF Module
- 868MHz or 915MHz selectable in field
- 30 configurable channels:
-- From 868,00 to 875,25 in steps of 0,25Mhz each channel.
-- From 915,00 to 922,25 in steps of 0,25Mhz each channel.- Auto-link with communication Habs (easy setup).
- Upgradable firmware.
SMARTair® Escutcheon (Standalone)
The SMARTair wireless and battery powered escutcheons are ideal for transit, office or meeting room doors. The wide range of escutcheons offer a RFID reader amd locking mechanism in one for all kind of doors.
Technical Data
Door profiles - Suitable for wooden, narrow or glass doors
Traffic volume - meduim to high
Exterior usage - IP54 (Xetreme version) Up to 85% humidity -20 °C to +70 °C
Hardware compatibility and installation - High retrofit (compatible with most common mortise locks). Drilling, no cabling. Doors from 30mm up to 110mm (thicker doors may be possible on demand)
Power supply - Battery (from 60.000 to 80.000 cycles)* max. 2 years standby**
Types of batteries:: 3 LR03 AAA 1.5V alkaline batteries
Certification - CE (EMC, R&TTE). ROHS, REACH, WEE. EN1634 (Fire)
RFID tegnologies - HID iClass(R). MIFARE Classic and Ultralight DESFire.
System management upgradability - Escutcheons can be upgraded from standalone > Offline. Update on Card > Wireless online by:- Offline/UoC: firmware upgrade
- Wireless Online:
- Adding RF Module
- Fireware upgrade
- Change of internal cover (plastic top)
* Depending on reading technology (MIFARE), iClass etc.)
** Depending on cycles per day.
Electronic Technical Caracteristics
Reader Module- Activation Mode: The escutcheon is activated without any previous contact with the escutcheon, just approching the credential, ensuring an efficient power consumption.
- Reading distance: 2-4 cm read/write distance with standard RFID credentials.
- Emergency openingL Jack connection is available to connect the emergency kit and to open with emergency or user card..
- RFID reader with capacitive keypad and backlighting LEDs (green/red/blue) for different warning signals: access authorized or denied, low battery level, etc.
- Buzzer included for PIN confirmation and access denied.
Control Unit
- Upgradeable firmware.
- None-volatile memory.
- 100 PINS per device. (4-6 digits)
- 500 User cards per device.
- Operating Modes:
-- Standard: Default operating mode. Freewheeling handle until valid credential presented, then allows to open the door for 4-10 seconds.
-- Passage mode: Escutcheon is always in open mode (cofigured by zones or by authorized user after double badging or double PIN).
Battery Module- Easy battery change.
- All Users (Cards and PINs) sign low batteries during the reading (red and green led blink). For very low batteries red and green led will blink alternatively but the escutcheon will not grant the access.