      • eCLIQ User Key

        Function
        Used in combination with the eCLIQ cylinder, the eCLIQ User Key can be programmed directly with authorizations and time profiles.
        The key also collects usage information to create complete access audit trails.

        Applications
        The eCLIQ® User Key Available in three versions (Basic, Time and Dynamic).
        This key can be used with eCLIQ Remote Programming Devices.

        Features
        Schedule: 32 week-based time intervals
        Audit trail: 1000 events
        Color-coded LED indicators: Green - Authorized; Red - Unauthorized; Red-green-red - Out of schedule; Blinking red - Low battery
        Supports remote programming of authorizations and scheduling

        Specifications
        Protected against temporary immersion in water (IP67)
        Temperature range: 0°C - 70°C
        Encrypted (AES) communication between the key and the cylinder or software
        Powered by a CR2032 3V lithium battery; Battery replacement in the key does not require tools.
        Battery lifetime: 3 years or 30,000 operations
        Standard design: black; other colors are available for the key cover
        Special keys:
        - Beluga: Designed for use in outdoor installation (-30°C to +50°C), for example, storage in the fire service safe. The Beluga key's battery is not exchangeable.
        - ATEX certified: user keys that are certified for use in potentially-explosive areas in Zone 1 (II 2G Ex ib IIB T4)
        - RFID: Key with integrated RFID chip for integration into control of transponder-based systems, e.g. access control systems.

      • eCLIQ Local Programing Device (LPD)

        Function
        The eCLIQ® Local Programming Device (LPD) is used to connect eCLIQ® keys and cylinders to the software (CLIQ® Manager and/or CLIQ® Web Manager), via secure communication.

        Features
        Provides secure access to the eCLIQ® system software
        Reads and uploads audit trails from eCLIQ® keys
        Updates eCLIQ® Keys with the latest authorizations and time schedules
        Uploads tasks from CLIQ® software to the C-Key(s)

        Specifications
        Computer connectivity via micro USB cable
        Power supply: powered through the micro USB cable

      • CLIQ Web Manager Software

        Function
        A web-based software program, CLIQ® Web Manager is used to manage the eCLIQ® Remote system.
        User-friendly and intuitive, system administrators use it to remotely manage the day-to-day functionality of the eCLIQ® Remote system.

        Applications
        As a web-based solution, the CLIQ® Web Manager provides access to the system's database from any computer with an Internet connection and has been specifically designed to handle large, decentralized systems.

        Features
        Secure login via a control key and PIN code for multiple administrators
        Advanced search and filter options
        Manages and creates: Access permissions; Audit trails - including activities from remote devices; Time-based authorization; Recurring validation; Reports
        Supports remote programming device management
        Enables system grouping into manageable domains
        Allows remote key programming
        Key and personnel management

        Specifications
        Web browser: Internet Explorer 7 and up
        Highly secured network connections, 128-bit SSL encryption as well as the security afforded by software certificates on client and server
        Available in multi-language versions
        License options are available per system size

      • eCLIQ Remote Wall Programming Device (WPD)

        Function
        Embedded with its own IP address, the online eCLIQ® Remote Wall Programming Device allows users to remotely program eCLIQ User keys and C-Keys.

        Features
        Makes authorization changes in Dynamic keys
        Actions time-profile changes in Dynamic and Time keys
        Retrieves audit trails from Dynamic and Time keys
        Revalidates keys
        Automatically syncs keys' time settings
        Provides visual and audio indicators of operational status and activity progress
        Updates eCLIQ® key's firmware

        Specifications
        IP42
        Power supply: 12-24 V AC/DC or Power over Ethernet (PoE) - class 1 IEEE 802.3 af. (Supply must be LPS approved)
        'Anti vandal' model: IP65, Vandalism-resistant IK9

      • CLIQ Manager Software

        Function
        Locally installed CLIQ® Manager software is used for the day-to-day management of the eCLIQ® system. With it, system administers can perform a variety of tasks based on the specific needs of their environment.

        Features
        Secure login via a control key and PIN code
        Manages and creates: Access permissions; Audit trails; Time-based authorization; Reports
        Key and personnel management

        Specifications
        Installation options: Local installation; Centralized database
        OS - MS Windows 2000/XP/ VISTA/Windows 7/8/10
        Hardware requirements: MS Windows compatible PC, Pentium IV-1,5 GHz, 50MB free hard disk memory, 512 MB RAM

        Licensing options
        CLIQ® Manager 50 - One eCLIQ® system with up to 50 eCLIQ® elements in the system
        CLIQ® Manager 200 - One eCLIQ® system with up to 200 eCLIQ® elements in the system
        CLIQ® Single Manager - One eCLIQ® system with unlimited quantity of eCLIQ® elements
        CLIQ® Multi System Manager - Multiple eCLIQ® systems with an unlimited quantity of eCLIQ® elements

      • eCLIQ Cylinder

        Function
        The eCLIQ cylinder is used in combination with the eCLIQ key enabling the collection and storage of information about when the cylinder has been accessed and with which key.
        In addition, the cylinder stores a list of authorized and unauthorized eCLIQ keys to ensure only enabled keys have access.

        Applications
        The eCLIQ® cylinder is available in a wide range of cylinder applications including Euro (double or single), rim, mortise, kik, padlocks, and more.

        Features
        Audit trail standard memory: 100 events
        Audit trail extended memory: 1000 events

        Specifications
        IP54 (dust and rain protection cap available for one or both sides - IP55)
        Temperature range: -25°C - 85°C
        Encrypted (AES) communication between cylinder and key/c-key
        Available in a variety of finishes
        Minimum length: 28 mm (Euro model)
        Modular (from 30mm, by 5 or 10mm extentions)
        Maintenance-free up to 200,000 cycles (includes integrated lubricant reserve)
        Power supplied via the eCLIQ® key's embedded battery

      • eCLIQ Remote Mobile Programming Device (MPD)

        Function
        Using a cellular phone or computer as a modem, the eCLIQ® Remote Mobile Programming Device (MPD) allows user to program eCLIQ® keys and C-Keys on-the-go.

        Features
        Makes authorization changes in Dynamic keys
        Actions time-profile changes inTime keys
        Retrieves audit trails from Dynamic and Time keys
        Revalidates keys
        Automatically syncs keys' time settings
        Provides visual and audio indicators of operational status and activity progress

        Specifications
        IP42
        Powered by 4 x AAA batteries

        Connection options
        Via cellular telephone through Bluetooth. Connects to conventional cellular telephone models without the need for software installation
        Via computer through USB connection between Mobile PD and computer using a simple application as a bridge for network connections. Can be powered through the USB cable.

      • eCLIQ Control Key (C-Key)

        Function
        The eCLIQ® Control Key (C-Key) manages the electronic communication provided by the eCLIQ® system.
        It provides users secure access to the system software and the ability to transfer information between the software and cylinders.

        Applications
        Each eCLIQ® system must have at least one C-Key, referred to as the Master C-Key (MCK). The MCK is used to transfer information from eCLIQ® cylinders to the software and not to open them.
        For systems with more than one administrator, it is possible to utilize additional C-Keys, also referred to as a Normal C-Key (NCK).

        Features
        Update key authorization lists within cylinders
        Transfers audit trail information from cylinder to software
        Facilitates secured access to the software

        Specifications
        Protected against temporary immersion in water (IP67)
        Temperature range: 0°C - 70°C
        Encrypted (AES) communication between the key and the cylinder or software
        Powered by a CR2032 3V lithium battery; Battery replacement in the key does not require tools.
        Battery lifetime: 3 years or 30,000 operations
        Standard desigh: black; other colors are available for the key cover
        Special keys:
        - Beluga: Designed for use in outdoor installation (-30°C to +50°C), for example, storage in the fire service safe. The Beluga key's battery is not exchangeable.
        - ATEX certified: user keys that are certified for use in potentially-explosive areas in Zone 1 (II 2G Ex ib IIB T4)
        - RFID: Key with integrated RFID chip for integration into control of transponder-based systems, e.g. access control systems.